Search Results for splitting-tensile-strength

Article
MECHANICAL PROPERTIES FOR ORDINARY CONCRETE CONTAINING WASTE PLASTIC FIBERS

Khalil Ibrahim Aziz, Huda Al Moqbel kuhair

Pages: 33-44

PDF Full Text
Abstract

This study program has been conducted to investigate the influence of adding waste plastic fibers (WPF) resulting from manual cutting for bottles used in the conservation gassy beverage on different characteristics of ordinary concrete. Cutting plastic waste by volumetric rates ranging between (0.5%) to (2%) was approved. Reference mix was produced for comparison. Tests were conducted on the models produced from waste plastic fiber concrete like compressive strength, flexural strength and splitting tensile strength. The analysis of the results showed that the use of plastic waste fibers (1%) has led to improve the properties of flexural strength and splitting tensile strength compared with reference concrete .When the( 0.75%)WPF ratio improved the compressive strength as compared with the control specimen . Compressive strength in (28 days) with fiber ratio (0.75%) WPF is higher than equal (5.1%) from compressive strength in (28 days) of reference concrete. Volumetric ratio (1%) WPF can be also observed that each of the flexural strength and splitting tensile strength increases equal (12.5 and 12.5%) respectively, from flexural strength and splitting tensile strength for the reference mix at(28day).

Article
Utilization of Municipal Solid Waste Ash in Concrete by partial Replacement of Cement

Faaeza Ahmed Abd Ul-Kareem

Pages: 57-66

PDF Full Text
Abstract

The problem of solid waste is being emerged increasingly due to the increased quantity of solid waste as a result of population’s increase .From the point of view of environmental and energy concerns, it is preferable to reuse the organic and inorganic components of solid waste in order to minimize the cost. In this investigation, the possibility of using solid waste ash (SWA) as a partial replacement of cement and its effect on the mechanical properties of concrete was studied. Samples of municipal solid wastes were collected were burring and changed to ash. A total of 50 cubes, 15 small cubes, and 30 cylinders, as well as 5 prisms were prepared .Various properties of solid waste ash are added to the cement mistures with percent's of 5, 10, 15 and 20 percent by weight of solid waste ash. A concrete mix with a percent solid waste ash was used as reference. Pozzolanic activities of all mortars, and setting times of all pastes, and workability of all mixes were investigated .Compressive strength, splitting tensile strength, absorption, and drying shrinkage for reference for reference and solid waste concrete specimens were investigated at various ages. Results demonstrate that the pozzolanic activity was within ASTM requirements for the cases of 5% and 10% ash replacement. For 15 and 20 percent replacement this activity was only slightly less than the ASTM value. The 90-day compressive strength rose, in comparison with control specimens, with 5 percent replacement and was only slightly lower at 10 percent replacement. In splitting tensile strength was at least equal to reference specimens for all replacement ratios. The rise in these values, over the reference specimens, ranged between 0 to 21 percent for the case of 20 and 5 percent replacement, respectively.

Article
High-Velocity Impact Strength of Plain and Fiber- Reinforced Polymer-Modified Concrete

Bayan S. Al-Numan .

Pages: 1-25

PDF Full Text
Abstract

AbstractThis study deals with establishing high-velocity impact properties of polymer –modified concrete (PMC) including Styrene-Butadiene rubber (SBR), with different weight ratios of polymer to cement: 4%, 8% and 12%. Steel fibers were also included. Sixteen (500mm) diameter, (50mm) thick discs for high-velocity impact tests were used. In addition compressive strength, splitting tensile strength, and flexural strength (modulus of rupture) were companionly recorded. In all the tests, concrete was with and without crimped steel fibers of ratio 1% by volume.In investigating high-velocity impact strength, the decrease in projectile penetration depth was (5-17%) and the scabbing area reduced (15-35%) over reference concrete.In studying PMC including 1% by volume steel fibers, an additional increase was observed in all properties. The increases were quite significant in high-velocity impact strengths. Further reduction was recorded in scabbing area of (64-95%) and penetration depth reduced (28-39%) over control specimens. The fragmentations were reduced also. The range of corresponding compressive was (48-64)MPa ,of splitting tensile strength (4.2-7.8) MPa, and of flexural strength (5-8) MP      

Article
تأثیر إضافة الکبریت إلى الخلطة الخرسانیة

nan nan

Pages: 32-40

PDF Full Text
Abstract

This research includes study of the of effect of adding sulphur, which is obtained from Samrraa factory on the properties of concrete like compressive strength, flexural strength and splitting tensile strength. The concrete mixes were: (1:8.5:8.5:7), (1:8.5:8.5:9), (1:8.5:8.5:12) and (1:1.5:3:0) (cement: sand: gravel: sulphur) respectively. The results refer to increasing of compressive strength , flexural strength and splitting tensile strength with increasing of sulphur ratio but increasing decreased at age (28)day with respect to ordinary concrete (sulphur ratio=0%).

Article
Some properties of light weight concrete containing carbon fiber

Aly AL- Attar, Israa.Y.Al- Hyally, Shakir A. AL-Mishhadani

Pages: 46-58

PDF Full Text
Abstract

Abstract:-This investigation studies the mechanical characteristics of carbon fiber reinforcedlight weight aggregate concrete, containing different percentages of fiber. The effect ofusing high range water reducing agent (SP) with 8% silica fume (SF) and 8% highreactivity Metakaolin (HRM), as a partial replacement by weight of cement, on thebehavior of (LWA) concrete is also studied.This investigation was carried out using several tests. These tests were workability freshand hardened density, compressive strength, splitting tensile strength and modulus ofrupture. Tests were performed for specimens at ages of (7,28,60,90 and 180) days . Thetest results indicated that the inclusion of carbon fiber to the light weight concrete mix didnot affect the compressive strength significantly, while the splitting tensile strength andthe modulus of rupture were improved significantly. The addition of silica fume andmetakaolin improves the compressive, splitting tensile , and modulus of rupture strengthsof carbon fiber light weight concrete. The average improvement was about (26.5%, 71%and 73 %) respectively for carbon fiber LWA concrete containing silica fume and (28%,72% and 75%) respectively for carbon fiber LWA concrete containing high reactivitymetakaolin.

Article
Mechanical, thermal and acoustical properties of concrete with fine Polyvinyl chloride (PVC)

Hamid H. Hussein, Osama A. Eedan, Mahmoud K. Ahmed

Pages: 81-91

PDF Full Text
Abstract

This study addressed some important tests for concrete including thermal, acoustic insulation and some mechanical behaviour of concrete containing granular Polyvinyl Chloride (PVC) waste as a sand replacement. The PVC waste was collected from a plant of manufacturing PVC doors and windows, was used to replace some of fine aggregate at ratios of 2.5%, 5%, 7.5%, 10%, 12.5% and 15% by weight Properties that studied are thermal conductivity, acoustic insulation slump, fresh density, dry density, compressive strength, flexural strength, and splitting tensile strength. Curing ages of 7, 28, and 56 days for the concrete mixtures were applied in this work. From the results of this study, it is suggested that using of 12.5% fine PVC as a sand replacement by weight can improve thermal insulation to about 82.48% more than concrete without plastic waste Acoustic insulation is about 43.09% more than reference mix and it satisfies the requirement of ACI 213R 2014 for structural lightweight concrete.

Article
Properties of Sustainable Self Compacting Concrete Containing PET Waste Plastic with Various Cement Replacement Materials

Hind abdulminem, Mahmoud Mohammed

Pages: 45-59

PDF Full Text
Abstract

This main aim of this study is evaluate wide range of fresh and hardened properties of sustainable self-compacting concrete containing various types of Cement Replacement Materials with optimum contents of Polyethylene Terephthalate PET waste plastic as fibers and fine aggregate replacement. This is to evaluate effect of the two forms of PET and to determine the best CRMs could be used with sustainable SCC. such as limestone, glass powder and fly ash with high replacement rate of 70% by weight of cement were used while fourth one (kaolin) was used with replacement rate of 20%. PET fibers were added to SCC with an aspect ratio of 24.4 and 0.7% volume fraction whereas fine aggregate partially replaced by 4% of waste plastic. Four reference mixtures contained FA, LP, GP and KA only, same four mixtures contained 0.7% PET fibers by volume, and the other same four mixtures contained 4% PET fine aggregate by volume. The obtained results all tested fresh properties, which include slump flow, T500, L-Box and segregation resistance were within the limits of the specification reported in EFNERC guidelines. Further, the forms PET have an adverse effect fresh properties of SCC. As for hardened properties (compressive strength, splitting tensile strength, flexural strength and impact strength). Further, this produced type of SCC showed an range of compressive strength (15.2-31.64 MPa) at 28 days. It can be from the current study the best CRMs to be used in SCC containing PET wastes was FA in terms of most tested properties.

Article
Study of Production and Some Properties of Foamed Concrete

Ibrahim A. S. Al-Jumaily, Ayad A.S. Al-Jumaily, Ameer Abdul-Rahman Al-Duleimy

Pages: 37-53

PDF Full Text
Abstract

SUMMARY This research work includes three main experimental stages. The first stage includes the production of foamed concrete. It is divided into two parts; in the first, mixing design (determination of the proportions of the raw materials) according to the required density was presented and in the second part, the mixing procedure has been illustrated. The second stage includes preparation of samples,(i.e. molding, finishing surface, removal from molds and curing). The third stage includes several tests to estimate properties of the final product and factors influencing them . These properties include density , compressive strength , splitting tensile strength and flexural strength. For foamed concrete with 800 kg/m3 density, the 28-day compressive strength is from (1.334 MPa) to (2.323 MPa), while with 1600 kg/m3 density, the strength is from (7.015 MPa) to (9.591 MPa). For 1600 kg/m3 density foamed concrete, the 28-day flexural strength range is from (1.08 MPa) to (2.205 MPa).

Article
Experimental Investigation on Mechanical Properties of Normal Concrete Reinforced with Discarded Steel Fibres

Rawaa Obaid, Ahmed Noaman, Akram Mahmoud

Pages: 1-9

PDF Full Text
Abstract

This study presents an investigation of the mechanical properties of normal concrete reinforced with discarded steel fibers (DSFs) resulting from tire manufacturing. DSFs were added to concrete in two different volume fractions of (0.25 %, and 0.5 %), and these fibers have dimensions of (40 mm length×0.92 mm diameter). The results showed that the compressive strength of the concrete was enhanced by (8.8%, and 3.3%) by adding of DSFs. However, the workability of concrete decreased at all added ratios. While the density is slightly changed. Also, the results indicate that the modulus of elasticity shows slight increases by (3.06%, and 2.25%). Additionally, the incorporation of DSFs improves the splitting tensile strength and modulus of rupture significantly. For concrete mixes having volume fractions of 0.25% and 0.5%, the splitting tensile increased by (7.89%, and 23.68%), and the modulus of rupture increased by (6.67% and 25.58%), respectively. It was concluded that using this type of discarded fibers can improve the mechanical properties of concrete as an alternative type for other types of industrial fibers.

Article
Flow ability and Mechanical Properties of Shotcrete concrete incorporated with Waste Plastic Fibers

Amer Enad, Abdulkader Al-Hadithi, Yousif Mansoor

Pages: 8-15

PDF Full Text
Abstract

Polyethylene terephthalate (PET) fiber is a green-friendly fiber that is capable of enhancing the mechanical properties of wet-mixing shotcrete. The main purpose of this study is to see how varied volumes of waste plastic fibers (WPF) affect the flowability and mechanical properties of wet-mix shotcrete. For this aim, a variety of experimental tests based on WPF content were chosen. Fresh and mechanical tests included slump, T500, density, compressive strength, and splitting strength were applied. The results shown a improved in shotcrete performance as the WPF content increased. Among all fitting correlations, density and compressive strength revealed the strongest linear ship association. Due to greater interlocking between WPF and concrete matrix, WPF was a major use in enhancing splitting tensile strength. WPF had the most influence on splitting strength, with 23–31 percent, 7–23 percent, and 6–38 percent for 7, 14, and 28-day, respectively.

Article
The possibility of using Polyethylene terephthalate (PET) as a fibre to improve the ductile behaviour of concrete

Hamid Hamood Hussein ., Osama Abd Al-Ameer ., . Mahmoud Khaled Ahmed

Pages: 30-39

PDF Full Text
Abstract

To preserve the natural materials, applying the principles of sustainable engineering, to approach the principle of zero waste and to contribute the solution of the negative environmental impact of two decades, which is caused by excessive use of bottles of polyethylene terephthalate (PET) in packaging, has led to the approach of alternative, clean and innovative technologies aimed at recycling and reuse to address this environmental problem. Proposed re-use empty bottles as a way to get rid of them and benefit from them at the same time the way, this method through which the empty bottles cutting into fibres using these fibres made of PET to improve the properties of concrete. Percentage of fiber that has been used are 1%, 1.5%, 2%, 3%, 4%, and 5%. Suitable tests were performed to measure properties of concrete reinforcement by recycle PET fibre such as compressive strength, splitting tensile strength, four-point bending strength, modulus of elasticity and toughness index. Flexural toughness tests were performed to measure the ductility capacities of reinforced concrete members with recycled PET fibre reinforced concrete. The results obtained indicate Toughness index was enhanced by using PET fibre reinforced concrete specimens, compared to no ductility performance of concrete specimens without fibre reinforcement. A significant change in ductility was when observed PET used fibre with 3%.    

Article
Mechanical Properties of FiberWaste Tire Concrete

Khalid Battal Najim

Pages: 97-110

PDF Full Text
Abstract

Abstract:Many of researchers study the uses of chopped worn-out tires as a replacementmaterial to production special types of concrete. In presented work, the worn-out tireswere used as fibers which have dimensions of 1×1×3 cm. The fibers used as a partialreplacement from volume of coarse aggregate. Two mixes of fiber worn-out tires(F.W.T.) concrete in addition to reference mix were selected, using PartialReplacement Ratio (PRR) of 20% and 30%. The tests which were used in this studywere: compressive strength, splitting tensile strength and flexural strength. It wasfound that incorporating of F.W.T. in concrete effected negatively on most propertiesof concrete, for example the percentage decreases in compressive strength relative toreference mix at 28 day were 20% and 27.3% for concrete with 20% and 30% F.W.T.by volume of coarse aggregate respectively. However, it gave good indicator to beutilized as a new construction material in many applications.

Article
The Effects of adding Waste Plastic Fibers on the Mechanical Properties and Shear Strength of Reinforced Concrete Beams

Abdulkader Ismail Al- Hadithi, Mustafa Ahmed Abbas

Pages: 110-124

PDF Full Text
Abstract

The concept of sustainability was developed in the last years and included the construction industry to solve the issues that pertaining by high consumption of natural sources, environmental pollution and high amount production of solid wastes. On the other hand, the plastics generation is growing exponentially every year, especially, types of Polyethylene Terephthalate (PET) that are used to produce soft drinks bottles, this study attempts to apply the concept of sustainability and reduce the environmental pollution by cutting the plastic bottles (PET) as small fibers added to the ordinary concrete to improve the shear and tensile strength of reinforced concrete beams. For this purpose, the experimental work was carried out to study the effect of waste plastic fibers (PET) on the shear behavior of seven reinforced concrete beams with dimensions of (100×150×1200) mm that were designed to fail in shear, the fibers percentages that were used in this study are (0.25, 0.5, 0.75, 1, 1.25 and 1.5%). Also, the influence of Polyethylene Terephthalate (PET) fibers on the mechanical properties of concrete was studied such as: workability, compressive strength, splitting tensile strength, static modulus of elasticity and ultrasonic pulse velocity.

Article
Mechanical Properties of Porcelinite Reinforced Concrete Beams

Ayad A. Slaby, Khalil I. Aziz, Ali Farhan Hadeed

Pages: 1-24

PDF Full Text
Abstract

The researches in Iraq has expanded in the field of material technology involving the properties of the light weight concrete using natural aggregate aviable in westran of Iraq. Researches work on porcelinite concrete has been carried out in several Iraqi Universities. The study is deals with mechanical properties of porcelinite aggregate concrete by casting (273) different specimens. These properties are, compressive strength, flexurale strength, splitting strength, static modulus of elasticity and absorption. The results indicated that the structural light weight aggregate concrete produced from local porcelinite aggregate is suitable to used as a structural concrete, it can produce structural light weight concrete of compressive strength varies from (23.0 to 29.8) MPa with the density ranges from (1745 to 1855) kg/m3, by using cement content about (550 and 650) kg/m3.Such concrete exhibited good mechanical properties. It gave the values of splitting tensile strength, modulus of rupture and modulus of elasticity, 75%, 90% and 60% from those of normal weight concrete respectively owning the same compressive strength and meeting the requirement of ACI-213

Article
The effect of high-temperature on concrete properties and the role of waste pozzalanic material to increase concrete resistance, A review

Amer Jamel, Sheelan Hama

Pages: 150-156

PDF Full Text
Abstract

The performance of the structural materials (concrete and steel reinforcement) and the behavior of the structural members after they were exposed to high temperatures have been considered the main topics of the current literature review. All varieties of concrete mixtures lost their compressive strength after 300˚C, even though there was no discernible strength loss between 150 and 300˚C. It was also discovered that the heating time had no appreciable impact on the strength loss when the exposed to heat less than 300 ˚C. Above 300 ˚C. Concrete begins to lose strength after being exposed for longer than one hour; the greatest loss of strength occurs during the first and second hours of exposure. Both the cured cement paste and the aggregates undergo chemical and physical changes at temperatures ranging from 600 °C to 900 °C. The 5% weighted rice husk ash (RHA) blended concrete still had an advantage in compressive strength, over the concrete when subjected to temperatures up to 700 C for two hours. Adding more recycled glass and ceramic particles to regular concrete increases its overall compressive and tensile strengths. Concrete becomes more durable and has fewer cracks when there is a higher replacement rate for ceramic and glass particles. The splitting tensile strength decreased with increasing temperature, changing from 60% to 70% of its initial strength after 600 °C. In this review, the better performance of concrete than the other concrete in terms of mechanical, physical, and durability properties at both room temperature and high temperature were concrete with 10% waste glass powder (WGP) substitution as a partial of cement and 10%–20% crushed glass (CG) substitution as a partial of aggregate .

Article
MECHANICAL PROPERTIES OF FIBER WASTE TIRE CONCRETE

Khalid Battal Najim

Pages: 19-34

PDF Full Text
Abstract

ABSTRACT: Many of researchers study the uses of chopped worn-out tires as a replacement material to production special types of concrete. In presented work, the worn-out tires were used as fibers which have dimensions of 1×1×3 cm. The fibers used as a partial replacement from volume of coarse aggregate. Two mixes of fiber worn-out tires (F.W.T.) concrete in addition to reference mix were selected, using Partial Replacement Ratio (PRR) of 20% and 30%. The tests which were used in this study were: compressive strength, splitting tensile strength and flexural strength. It was found that incorporating of F.W.T. in concrete effected negatively on most properties of concrete, for example the percentage decreases in compressive strength relative to reference mix at 28 day were 20% and 27.3% for concrete with 20% and 30% F.W.T. by volume of coarse aggregate respectively. However, it gave good indicator to be utilized as a new construction material in many applications.

1 - 16 of 16 items

Search Parameters

Journal Logo
Iraqi Journal of Civil Engineering

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.