Article
The Environmental Effect Reduction On Internal Space Temperature By External Walls Covering (Experimental Study)

Atif Ali Hassan

Pages: 45-58

PDF Full Text
Abstract

The object of this paper was reduced the heat transferred quantities from or to internal building space by covering it's external walls with many materials, therefore, the researcher build the (1x1x2) m room sample at 3rd floor for building in Baghdad city (L = 33.2 N°), and (1x2)m wall has East orientation , while the other surfaces were insulated by 200 mm styropor sheets, and using Air – Conditioner 0.5 Ton of refrigeration to afford the standard thermal comfort. The researcher found that, the metal sheet painted with thermal plastic paint with 10 mm thermal insulation used as a cover layer for ordinary wall saved 57% from electrical energy consumption in Air-Conditioner, while used that material without insulation layer gives 46.2% , hollow plastic board (for decorative used) gives 42.5% , hollow faced brick with thermal insulation gives 40.22%, solid flooring brick with thermal insulation gives 39.5% , colour metal sheets with air – gap gives 36.4%, asbestos – cement board coated by reflective aluminum paint gives 34%, the ceramic with thermal insulation gives 31.9%, while all the material – marble , porcelene , hallan stone , fiberglass sheets with 10 mm thermal insulation will gives the electrical energy reduction percentage less than 30% .

Article
Mechanical, thermal and acoustical properties of concrete with fine Polyvinyl chloride (PVC)

Hamid H. Hussein, Osama A. Eedan, Mahmoud K. Ahmed

Pages: 81-91

PDF Full Text
Abstract

This study addressed some important tests for concrete including thermal, acoustic insulation and some mechanical behaviour of concrete containing granular Polyvinyl Chloride (PVC) waste as a sand replacement. The PVC waste was collected from a plant of manufacturing PVC doors and windows, was used to replace some of fine aggregate at ratios of 2.5%, 5%, 7.5%, 10%, 12.5% and 15% by weight Properties that studied are thermal conductivity, acoustic insulation slump, fresh density, dry density, compressive strength, flexural strength, and splitting tensile strength. Curing ages of 7, 28, and 56 days for the concrete mixtures were applied in this work. From the results of this study, it is suggested that using of 12.5% fine PVC as a sand replacement by weight can improve thermal insulation to about 82.48% more than concrete without plastic waste Acoustic insulation is about 43.09% more than reference mix and it satisfies the requirement of ACI 213R 2014 for structural lightweight concrete.

Article
Simple roofing system suitable for buildings in hot climate and it's effect on energy conservation (Experimental study)

Atif Ali Hasan

Pages: 1-13

PDF Full Text
Abstract

The objective of this paper is reduced the electrical energy which used in air-condition system by replaced the common roofing system by the another which more suitable for hot climate area. The researcher was build (1x1x3)m sample room at 3rd floor in building at Baghdad city (33.2 °N) for 200mm polystiran thermal insulation for other room surfaces and air-conditioner of 0.5 Ton of refrigeration capacity is used to maintain the standard thermal comfort, the roof thermal behavior study for 15 hr/day, at day 21 from five each months (Jan, March, June, July & September). It was found the suggested roofing system reduced the dead load by 300kg/m2 and the electrical energy which used in air-conditioning system reduced by 37% when used open air gap was used, and become 30% when has used closed air gap has used and became 27% relation to ordinary system.

1 - 3 of 3 items

Search Parameters

Journal Logo
Iraqi Journal of Civil Engineering

University of Anbar

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

       
Copyright © 2025 College of Engineering, University of Anbar. All rights reserved, including those for text and data mining, AI training, and similar technologies.